What is an RPZ valve?
A reduced pressure zone valve is a Type BA backflow prevention device. It uses two check valves and a relief valve to stop contaminated water flowing back into the supply, protecting against risks up to fluid category 4.
An RPZ valve test certificate records the commissioning or annual test of a reduced pressure zone valve, the Type BA backflow prevention device used to protect the water supply against backflow up to fluid category 4. It confirms the valve is operating correctly and protecting the supply.
Free plan · No card required · Works offline on site
RPZ valves are covered by the Water Supply (Water Fittings) Regulations 1999 and BS EN 12729, and water suppliers expect each device to be tested when installed and then at least annually by an approved tester, with the results reported to the water undertaker.
TradePlanr lets you record the device details, gauge readings and test results on site and produce a clear PDF certificate, so the test is documented for the customer and the water supplier without extra office work.
An RPZ valve must be tested when it is first installed and then at least once a year, as well as after any maintenance or repair. The test confirms the device still protects the supply against backflow at up to fluid category 4.
Testing is carried out by an approved RPZ tester using calibrated gauges, following the method in BS EN 12729 and the water industry guidance. The result is normally reported to the water supplier as well as the person responsible for the premises.
The certificate is the evidence that the device has been tested and passed. Sites such as commercial kitchens, plant rooms, laboratories and irrigation systems rely on it to show their backflow protection is being maintained.
Record the property, the valve location and the device make, model, size and serial number, along with the fluid category it protects against.
Log the gauge readings across the check valves and the relief valve opening point, following the BS EN 12729 test method.
Enter the pass or fail result, note any remedial work needed and set the next test due date so the annual test is not missed.
Capture the signature, generate the PDF test certificate and store it against the site, ready to send to the customer and report to the water supplier.
TradePlanr generates this and 45+ other gas, electrical, oil, plumbing and renewables certificates as proper PDFs — filled on site, signed on screen and stored against the job. Works even with no signal. Free to start.
A reduced pressure zone valve is a Type BA backflow prevention device. It uses two check valves and a relief valve to stop contaminated water flowing back into the supply, protecting against risks up to fluid category 4.
At commissioning and then at least annually, plus after any maintenance or repair. Water suppliers expect the test to be carried out by an approved tester and the results reported to them.
BS EN 12729 covers Type BA devices, and testing follows the recognised water industry method under the Water Supply (Water Fittings) Regulations 1999.
Yes. TradePlanr lets you record the device details, gauge readings and result, capture the signature and produce the PDF at the property.
The compliance record for plumbing work under the Water Supply (Water Fittings) Regulations 1999.
The Legionella risk assessment for domestic and commercial water systems to ACOP L8 / HSG274.
The pressure/soundness test record for new or altered water and heating pipework.